Ball check valve is simple and compact and commonly used to protect wastewater pumps where economy is important.
BELGICAST provides a range of threaded ends and flanged ball check valves, for sewage water and loaded or viscous fluids. This check valve consists of a ductile iron body with internal design guiding a rubber-coated ball out of the seat by the flow to its upper housing, then moving it back to the seat when the flow reverses.
Threaded type: 1" to 3"
Flanged type: DN40 up to 400
Working pressures: 16 bar up to DN200, 10 bar for DN250 to DN400
"BSP" profile thread according to standards ISO 228-1 and NF E 03-005
Flanges drilling according to standard EN 1092-2 and ISO 7005-2: ISO PN10 or 16 up to DN200, ISO PN10 from DN250 to DN400
Face to face dimensions for flanged type: according to standards EN 558-1 series 48 and ISO 5752 series 48
Medium Temperature: -10°C up to +80°C